Överensstämmelse avseende industristandard |
---|
Elektromagnetisk kompatibilitet | FCC Class A; FCC part 15 Class A; ICE-003, Canadian Radio Interface Regulation; VCCI Class A; EN 55022/CISPR 22 Class A |
Immunitetsstandard | EN 55024, CISPR 24; IEC 61000-4-2; 4 kV CD, 8 kV AD; IEC 61000-4-3; 3 V/m; IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line); IEC 61000-4-5; 1 kV/2 kV AC; IEC 61000-4-6; 3 V; IEC 61000-4-8; 1 A/m, 50 or 60 Hz; IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3 |
Överensstämmelse avseende industristandard | EN: EN 55024, CISPR 24; ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3; 3 V/m; EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5; 1 kV/2 kV AC; Conducted: IEC 61000-4-6; 3 V; Power frequency magnetic field: IEC 61000-4-8; 1 A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods; Harmonics: EN 61000-3-2, IEC 61000-3-2; Flicker: EN 61000-3-3, IEC 61000-3-3 |
Säkerhet | CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950; IEC 60825 |
Ljudtryck (standby) |
---|
Ljudtryck | Power: 63.0 dB, Pressure: 47.8 dB, ISO 7779, ISO 9296 |
Drifthöjd | up to 3 km |
Luftfuktighet vid drift | 15 to 95% @ 131°F (55°C) (noncondensing) |
Luftfuktighet vid förvaring | 15 to 95% @ 149°F (65°C) (noncondensing) |
Driftstemperatur | 0 to 45°C |
Förvaringstemperatur | -40 to 70°C |
Adapteranslutning |
---|
Värmeavgivning | 4900 BTU/hr (5170 kJ/hr) |
Not om värmeavgivning | (max. non-PoE); 7400 BTU/hr (7807 kJ/hr) (max. PoE) |
Routingtabellstorlek | 10000 entries |
Switch fabric-hastighet | 1.1 Tbps |
Kapacitet för routing/switching | 993.6 Gbps |
Adresstabellstorlek | 64000 entries |
Administrationsfunktioner | IMC - Intelligent Management Center; Command-line interface; Web browser; Configuration menu; Out-of-band management (serial RS-232c) |
Kommunikation | RFC 1591 DNS (client); HTML and telnet management; IEEE 802.1ad Q-in-Q; IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3af Power over Ethernet; IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058; RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP; RFC 4675 RADIUS VLAN & Priority; RFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode; RFC 4601 Draft 10 PIM Sparse Mode; RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6; RFC 4541 IGMP & MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2328 OSPFv2; RFC 3101 OSPF NSSA; RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF); IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv2 Secure Shell |
BGP | RFC 1997 BGP Communities Attribute; RFC 2918 Route Refresh Capability; RFC 4271 A Border Gateway Protocol 4 (BGP-4); RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP); RFC 4724 Graceful Restart Mechanism for BGP; RFC 5492 Capabilities Advertisement with BGP-4 |
DoS-skydd | CPU DoS Protection |
Enhetsadministration | RFC 1591 DNS (client); HTML and telnet management |
Allmänna protokoll | IEEE 802.1ad Q-in-Q; IEEE 802.1AX-2008 Link Aggregation; IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3af Power over Ethernet; IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP; RFC 4675 RADIUS VLAN & Priority; UDLD (Uni-directional Link Detection) |
IP Multicast | RFC 3376 IGMPv3 (host joins only); RFC 3973 PIM Dense Mode; RFC 4601 PIM Sparse Mode |
IPv6 | RFC 1981 IPv6 Path MTU Discovery; RFC 2375 IPv6 Multicast Address Assignments; RFC 2460 IPv6 Specification; RFC 2464 Transmission of IPv6 over Ethernet Networks; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client and relay); RFC 3484 Default Address Selection for IPv6 ; RFC 3587 IPv6 Global Unicast Address Format; RFC 3596 DNS Extension for IPv6; RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6; RFC 4022 MIB for TCP; RFC 4087 IP Tunnel MIB; RFC 4113 MIB for UDP; RFC 4213 Basic Transition Mechanisms for IPv6 Hosts and Routers ; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4291 IP Version 6 Addressing Architecture ; RFC 4293 MIB for IP; RFC 4294 IPv6 Node Requirements; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6; RFC 4541 IGMP & MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 5095 Deprecation of Type 0 Routing Headers in IPv6 ; RFC 5340 OSPFv3 for IPv6; RFC 5453 Reserved IPv6 Interface Identifiers; RFC 5519 Multicast Group Membership Discovery MIB (MLDv2 only) ; RFC 5722 Handling of Overlapping IPv6 Fragments |
MIB | IEEE 802.1ap (MSTP and STP MIB's only); RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2933 IGMP MIB |
Nätverkshantering | IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON |
OSPF | RFC 2328 OSPFv2; RFC 3101 OSPF NSSA; RFC 3623 Graceful OSPF Restart (Unplanned Outages only); RFC 5340 OSPFv3 for IPv6 |
QoS/Cos | RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF) |
Säkerhet | IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; RFC 3579 RADIUS Support For Extensible Authentication Protocol (EAP); Secure Sockets Layer (SSL); SSHv2 Secure Shell |
Latens | 1000 Mb Latency: < 3.7 µs; 10 Gbps Latency: < 2.1 µs |
Genomströmning | 739 Mpps |
Portar | 92 RJ-45 autosensing 10/100/1000 PoE+ ports; 2 SFP+ 10GbE ports; 8 open module slots; Supports a maximum of 288 autosensing 10/100/1000 ports or 96 10GbE ports or 288 mini-GBICs, or a combination; Included |
Friskrivning |
---|
Friskrivningsklausul | Product image may differ from actual product |
Snabbspecifikation |
---|
Webbadress för ytterligare information | http://www.hp.com/go/procurve/ |
Produktens yttermått (med efterbehandlingsenhet som tillval, metersystemet) |
---|
Minimimått (B x D x H) | 44.45 x 47.5 x 39.62 cm |
Kartongens vikt (kartong eller ytterförpackning) |
---|
Vikt | 46.61 kg |
Medföljer |
---|
Medföljer | (1) HP 8212-92G-PoE+-2XG v2 zl Switch, with Premium Software pre-installed |
Tekniska noteringar |
---|
Tekniska noteringar | Interface/Service modules, power supplies, and redundant management module must be ordered separately.RS-232C console port via an RJ-45 connector.When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, for example, J4858B, J4859C) are required. |
Garantialternativ |
---|
Garanti | Limited Lifetime warranty: Advance hardware replacement with next-business-day delivery (available in most countries). See www.hp.com/networking/warrantysummary for duration details. |
Processoruttag |
---|
Minne och processor | Freescale PowerPC 8540 @ 666 MHz; 4 MB flash; 128 MB compact flash; 256 MB DDR SDRAM |
Batterityp |
---|
Öppna uttag för strömförsörjning | 4 |
Strömförsörjning | Chassis ships without power supplies. Four power supply slots are available; three different power supplies are available. See power supply products for additional specifications.; Power supplies must be ordered separately. A minimum of two J8712A, J8713A, or
J9306A supplies are required to power the system. |
Infrekvens | 50/60 Hz |
Inspänning | 100 - 127/200 - 240 VAC |
Reläkapacitet |
---|
Strömförsörjningsenhetens namn | 2 x J9306A |
Montering | Mounts in an EIA-standard 19 in telco rack/equipment cabinet (hardware included); horizontal surface mounting only. An optional 4-post cabinet rail is available (see ordering guide). |
Format |
---|
Format | 9U height |